Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Adicionar filtros








Intervalo de ano
1.
Archives of Plastic Surgery ; : 33-41, 2020.
Artigo | WPRIM | ID: wpr-830695

RESUMO

Background@#Closed-suction drains are widely used in expander-based breast reconstruction. These drains are typically removed using a volume-based criterion. The drainage volume affects the hospital stay length and the recovery time. However, few studies have analyzed the factors that influence drainage volume after expander-based breast reconstruction. @*Methods@#We retrospectively analyzed data regarding daily drainage from patients who underwent expander-based breast reconstruction between April 2014 and January 2018 (159 patients, 176 expanders). Patient and operative factors were analyzed regarding their influence on total drainage volume and drain placement duration using univariate and multivariate analyses and analysis of variance. @*Results@#The mean total drainage volume was 1,210.77±611.44 mL. Univariate analysis showed correlations between total drainage volume and age (B=19.825, P<0.001), body weight (B=17.758, P<0.001), body mass index (B=51.817, P<0.001), and specimen weight (B=1.590, P<0.001). Diabetes history (P<0.001), expander type (P<0.001), and the surgical instrument used (P<0.001) also strongly influenced total drainage. The acellular dermal matrix type used did not affect total drainage (P=0.626). In the multivariate analysis, age (B=11.907, P=0.004), specimen weight (B=0.927, P<0.001), and expander type (B=593.728, P<0.001) were significant predictors of total drainage. @*Conclusions@#Our findings suggest that the total drainage and the duration of drain placement needed after expander-based breast reconstruction can be predicted using preoperative and intraoperative data. Patient age, specimen weight, and expander type are important predictors of drainage volume. Older patients, heavier specimens, and use of the Mentor rather than the Allergan expander corresponded to a greater total drainage volume and a longer duration of drain placement.

2.
Archives of Plastic Surgery ; : 330-335, 2019.
Artigo em Inglês | WPRIM | ID: wpr-762846

RESUMO

BACKGROUND: The use of anatomic implants has improved the aesthetic results of breast surgery; however, implant malrotation is an uncommon, but serious complication of these procedures. Nevertheless, little research has explored implant adhesion. In this study, we investigated adhesion between the expander and the capsule. METHODS: Seventy-nine cases of immediate breast reconstruction via two-stage implant-based reconstruction performed between September 2016 and November 2017 were evaluated. Mentor CPX4 expanders were used in 14 breasts, and Natrelle expanders in 65. We analyzed areas of adhesion on the surfaces of the tissue expanders when they were exchanged with permanent implants. We investigated whether adhesions occurred on the cephalic, caudal, anterior, and/or posterior surfaces of the expanders. RESULTS: Total adhesion occurred in 18 cases, non-adhesion in 15 cases, and partial adhesion in 46 cases. Of the non-adhesion cases, 80% (n=12) were with Mentor CPX4 expanders, while 94.4% (n=17) of the total adhesion cases were with Natrelle expanders. Of the partial adhesion cases, 90.7% involved the anterior-cephalic surface. The type of tissue expander showed a statistically significant relationship with the number of attachments in both univariate and multivariate logistic regression analyses (P<0.001) and with total drainage only in the univariate analysis (P=0.015). CONCLUSIONS: We sought to identify the location(s) of adhesion after tissue expander insertion. The texture of the implant was a significant predictor of the success of adhesion, and partial adhesion was common. The anterior-cephalic surface showed the highest adhesion rate. Nevertheless, partial adhesion suffices to prevent unwanted rotation of the expander.


Assuntos
Feminino , Humanos , Implante Mamário , Implantes de Mama , Mama , Drenagem , Modelos Logísticos , Mamoplastia , Mentores , Dispositivos para Expansão de Tecidos
3.
Archives of Plastic Surgery ; : 554-558, 2017.
Artigo em Inglês | WPRIM | ID: wpr-172625

RESUMO

In many cases of complete ear amputation, microvascular surgery is required for tissue perfusion and organ survival. However, microvascular reconstruction is not always feasible in the absence of suitable vessels. Here, we present the case of a 76-year-old man who underwent complete amputation of the left ear after a collapse at home because of cardiogenic syncope. He was treated with primary replantation and underwent a postoperative salvage course including continuous local hyperbaric oxygen therapy (HBOT), platelet-rich plasma (PRP) injections, and polydeoxyribonucleotide (PDRN) injections. The ear was almost completely salvaged, with a tiny eschar at the mid-scapha on both the anterior and posterior aspects. This case demonstrates the efficacy of local HBOT with PRP and PDRN injections.


Assuntos
Idoso , Humanos , Amputação Cirúrgica , Orelha , Oxigenoterapia Hiperbárica , Oxigênio , Perfusão , Plasma Rico em Plaquetas , Reimplante , Terapia de Salvação , Síncope , Sobrevivência de Tecidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA